IAI America XSEL-KX User Manual
Page 203
187
Part 4 Commands
ITER (Repeat)
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command, declaration
Output
(Output, flag)
Command,
declaration
Operand 1
Operand 2
Optional
Optional
ITER
Prohibited Prohibited
CP
[Function] Forcibly switch the control to EDDO while in a DOXX loop.
[Example 1]
DWEQ
1
0
Repeat the commands up to an EDDO command while
variable 1 contains “0.”
:
600
ITER
Forcibly switch the control to an EDDO command and
perform end judgment, if flag 600 is ON.
:
EDDO
EDDO (End DO WHILE)
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command, declaration
Output
(Output, flag)
Command,
declaration
Operand 1
Operand 2
Prohibited
Prohibited
EDDO
Prohibited Prohibited
CP
[Function] Declare the end of a loop that began with DWXX.
If the DWXX condition is not satisfied, the program will proceed to the step next to this
command.
[Example 1]
Refer to the section on DWXX.