(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
813
Maintenance information 3
Maintenance information (for analysis)
814
Maintenance information 4
Maintenance information (for analysis)
815
Maintenance information 5
Maintenance information (for analysis)
900
Blank step shortage error
There are not enough blank steps to save step data. Provide enough blank
steps needed to save step data.
901
Step number error
The step number is invalid.
902
Symbol-definition table number error
The symbol-definition table number is invalid.
903
Point number error
The point number is invalid.
904
Variable number error
The variable number is invalid.
905
Flag number error
The flag number is invalid.
906
I/O port/flag number error
The I/O port/flag number is invalid.
910
Command error (IAI protocol HT reception)
The command ID is not supported or invalid. (For future extension)
911
Message conversion error (IAI protocol HT reception)
The transmitted message does not match the message format or contains
invalid data. (For future extension)
930
Coordinate system number error
The coordinate system number is invalid.
931
Coordinate system type error
The coordinate system type is invalid.
932
Coordinate system definition data count-specification error
The specified number of coordinate system definition data is invalid.
933
Axis number error
The axis number is invalid.
934
Operation type error for SCARA ABS-reset special movement
The operation type for SCARA ABS-reset special movement is invalid.
935
Positioning operation type error
The positioning operation type is invalid.
936
Simple interference check zone number error
The simple interference check zone number is invalid.
938
Simple interference check zone data count-specification error
The specified number of simple interference check zone data is invalid.
939
Detection of entry into simple interference check zone (Message
level specification)
Entry into the simple interference check zone was detected. (Message level
specification)
93A
R-axis CP jog prohibition error when out of operation range (When
tool XY offset is valid)
Move into the operation range by jogging each axis.
A01
System-memory backup battery voltage-low warning
The voltage of the system-memory backup battery is low. Replace the battery.
(Above the minimum data-backup voltage)
A02
Abnormal system-memory backup battery voltage
The voltage of the system-memory backup battery is low. Replace the battery.
(Below the minimum data-backup voltage)
A03
Absolute-data backup battery voltage-low warning (Driver detection) The voltage of the absolute-data backup battery is low. Check the battery
connection or replace the battery.
A04
System mode error at core update
An update command was received when the system was not in the core update
mode. Before updating the core, confirm that a chip resistance for setting core
update mode is provided on the board. (For maintenance)