16 meter setting and adjustment – Toshiba Tosvert VF-AS1 User Manual
Page 92
E6581301
E-26
5
5.16
Meter setting and adjustment
HOUN
: FM terminal meter selection
HO
: FM terminal meter adjustment
H
: FM voltage/current output switching
H
: Inclination characteristic of FM output
H
: FM bias adjustment
COUN
: AM terminal meter selection
CO
: AM terminal meter adjustment
H
: Inclination characteristic of AM output
H
: AM bias adjustment
Note 1: The signal output from the FM and AM terminal is an analog voltage signal. (positive (+) side output. For
signed data, an absolute value is output. To output data with positive and negative sings, you need to use two
extended terminal boards (optional).)
Note 2: To the FM terminal, connect either a full-scale 0~1mAdc ammeter or a full-scale 0~7.5Vdc (or 10Vdc)
voltmeter, if necessary. The FM terminal can also be used as a 0(4)~20mAdc output terminal. To the AM
terminal, connect a full-scale 0-1mAdc ammeter.
Connect meters as shown below.
FM
CC
VF-AS1
The reading of the frequency meter fluctuates during calibration.
Meter: Frequency meter
(default setting)
+
-
+
A frequency meter QS60T is optionally available.
■
Output modes of the FM terminal
0-10V
0-20mA
0-1mA
FM
When used with a 0~1mAdc ammeter
SW2
When the optional frequency meter QS60T is
connected, this mode is selected.
0-10V
0-20mA
0-1mA
FM
When used with a DC0~10V voltmeter
SW2
H
=
0-10V
0-20mA
0-1mA
FM
When used with a 0(4)~20mAdc
SW2
H
=
AM
CC
VF-AS1
The reading of the ammeter fluctuates during calibration.
Meter: Ammeter
(default setting)
+
-
+
Make the maximum ammeter scale at least 150% of theinverter's rated output current.
• Function
Inverter’s operation data is sent to the FM terminal (AM terminal) as analog voltage signals. To display inverter’s
operation data, connect a meter to this terminal. The “FM terminal-connected meter adjustment HO” (AM
terminal-connected meter adjustment CO) parameter is used to calibrate the meter
.