E6581301

E-42

5

Default setting (V[R=)

Setting parameter V[R to resets all parameters except the following to their default settings.
+

When this parameter is set to 3, KPKV is displayed for a while, then switches back to the original display ( QHH

or ). Note that this setting also clears all trip history records. Trip history data will be cleared at this time.

Following parameters are designed considering maintenance that they cannot be reset to the factory default setting
even if you set the parameter V[R at . Following parameters are not displayed on the user parameter group
ITW

even if their settings are different from their default settings. So please be careful.

Title

Function

Title

Function

CWJ

History function

H

Optional AI2 input bias

HOUN

FM terminal meter selection

H

Optional AI2 input gain

HO

FM terminal meter adjustment

H

Logic output/pulse train output selection (OUT1)

COUN

AM terminal meter selection

H

MON1 terminal meter selection

CO

AM terminal meter adjustment

H

MON1 terminal meter adjustment

H

Analog VI/VII voltage/current switching

H

MON2 terminal meter selection

H

Analog AI2 (optional circuit board)
voltage/current switching

H

MON2 terminal meter adjustment

H

VI/II input bias

H

FM voltage/current output switching

H

VI/II input gain

H

MON1 voltage/current output switching

H

RR/S4 input bias

H

MON2 voltage/current output switching

H

RR/S4 input gain

H

RX input bias

H
H

Quick registration parameter 1~32

H

RX input gain

H

Free notes

H

Optional AI1 input bias

H

Network option reset setting

H

Optional AI1 input gain

Trip clear (V[R=)

Setting V[R to initializes the past four sets of recorded trip history data.
* (The parameter does not change.)

Cumulative operation time clear (V[R=)

Setting V[R to resets the cumulative operation time monitor to the initial value (0 [zero] time).

Initialization of type information (V[R=)

When a trip occurs because of a type error (GV[R is displayed), you can clear the trip by setting V[R to . This
function is used to reformat a control circuit board to adapt it to an inverter, for example, when a circuit board is
removed from an inverter to use another inverter for maintenance or for other reasons. This setting clears all type
data stored in the inverter.

Save user-defined parameters (V[R=)

Setting V[R to causes all the current parameter settings to be stored individually.

Reset of user-defined parameters (V[R=)

Setting V[R to returns all parameters to the settings saved by setting the parameter V[R=.
* The above settings and allows you to have your own default parameter settings.

Cumulative fan operation time clear (V[R=)

Setting V[R to resets the cumulative fan operation time to the initial value (0 [zero] time). Set this parameter
when replacing the cooling fan, and so on.

Acceleration/deceleration time setting: 0.01 to 600.0 sec. (V[R=)

When V[R is set to , the acceleration/deceleration time can be set within a range of 0.01 to 600.0 sec.

Acceleration/deceleration time setting: 0.1 to 6000 sec. (V[R=)

When V[R is set to , the acceleration/deceleration time can be set within a range of 0.1 to 6000 sec.