Toshiba Tosvert VF-AS1 User Manual
Page 249
K-1
1
E6581301
11
[10] Jump frequency
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f
Reference
H
0270
Jump frequency 1
0.0~HJ Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 12
H
0271
Jump step 1
0.0~30.0Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 12
H
0272
Jump frequency 2
0.0~HJ Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 12
H
0273
Jump step 2
0.0~30.0Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 12
H
0274
Jump frequency 3
0.0~HJ Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 12
H
0275
Jump step 3
0.0~30.0Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 12
[11] Preset speed operation frequency (8~15)
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f
Reference
H
0287
Preset speed operation
frequency 8
NN
~WN Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
5. 12
H
0288
Preset speed operation
frequency 9
NN
~WN Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
5. 12
H
0289
Preset speed operation
frequency 10
NN
~WN Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
5. 12
H
0290
Preset speed operation
frequency 11
NN
~WN Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
5. 12
H
0291
Preset speed operation
frequency 12
NN
~WN Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
5. 12
H
0292
Preset speed operation
frequency 13
NN
~WN Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
5. 12
H
0293
Preset speed operation
frequency 14
NN
~WN Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
5. 12
H
0294
Preset speed operation
frequency 15
(Forced operation frequency)
NN
~WN Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
5. 12
[12] Tripless intensification setup [1/2]
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f
Reference
EH
0300
PWM carrier frequency
1.0~16.0kHz (1.0~8.0kHz) *1
0.1/0.1
*2
Enabled
●/●
●/●
●
●
5. 17
WXU
0301
Auto-restart control selection
0:Deselect, 1:At auto-restart
2:ST ON/OFF switching, 3:1+2, 4:Starting
1/1
0
Disabled
●/●
●/●
●
●
5. 18.1
WXE
0302
Regenerative power ride-
through control
0:Deselect
1:Power ride-through
2:Deceleration stop during power failure
3:Synchronized deceleration/acceleration
(synchronized acceleration/deceleration signal)
4:Synchronized deceleration/acceleration
(synchronized acceleration/deceleration
signal+power failure)
1/1
0
Disabled
●/●
-/-
●
●
5. 18. 2
This parameter moves to a fundamental parameter. *1: For 200V-55/75kW models and 400V-90kW to 400V-280kW models, the carrier frequency is between 1.0 and 8.0kHz inclusive.
*2: Default values vary depending on the capacity.
⇒ See the table of K-46.
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)