Toshiba Tosvert VF-AS1 User Manual

Page 249

background image

K-1
1

E6581301

11

[10] Jump frequency

Vector control

Title

Communi

cation

No.

Function

Adjustment range

Minimum

setting unit

(Panel/Communi

cation)

Default

setting

Write during

running

Speed

control

Torque

control

PM

control

V/f

Reference

H

0270

Jump frequency 1

0.0~HJ Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 12

H

0271

Jump step 1

0.0~30.0Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 12

H

0272

Jump frequency 2

0.0~HJ Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 12

H

0273

Jump step 2

0.0~30.0Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 12

H

0274

Jump frequency 3

0.0~HJ Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 12

H

0275

Jump step 3

0.0~30.0Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 12

[11] Preset speed operation frequency (8~15)

Vector control

Title

Communi

cation

No.

Function

Adjustment range

Minimum

setting unit

(Panel/Communi

cation)

Default

setting

Write during

running

Speed

control

Torque

control

PM

control

V/f

Reference

H

0287

Preset speed operation

frequency 8

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

H

0288

Preset speed operation

frequency 9

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

H

0289

Preset speed operation

frequency 10

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

H

0290

Preset speed operation

frequency 11

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

H

0291

Preset speed operation

frequency 12

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

H

0292

Preset speed operation

frequency 13

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

H

0293

Preset speed operation

frequency 14

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

H

0294

Preset speed operation

frequency 15

(Forced operation frequency)

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

[12] Tripless intensification setup [1/2]

Vector control

Title

Communi

cation

No.

Function

Adjustment range

Minimum

setting unit

(Panel/Communi

cation)

Default

setting

Write during

running

Speed

control

Torque

control

PM

control

V/f

Reference

EH

0300

PWM carrier frequency

1.0~16.0kHz (1.0~8.0kHz) *1

0.1/0.1

*2

Enabled

●/●

●/●

5. 17

WXU

0301

Auto-restart control selection

0:Deselect, 1:At auto-restart

2:ST ON/OFF switching, 3:1+2, 4:Starting

1/1

0

Disabled

●/●

●/●

5. 18.1

WXE

0302

Regenerative power ride-

through control

0:Deselect

1:Power ride-through

2:Deceleration stop during power failure

3:Synchronized deceleration/acceleration

(synchronized acceleration/deceleration signal)

4:Synchronized deceleration/acceleration

(synchronized acceleration/deceleration

signal+power failure)

1/1

0

Disabled

●/●

-/-

5. 18. 2

This parameter moves to a fundamental parameter. *1: For 200V-55/75kW models and 400V-90kW to 400V-280kW models, the carrier frequency is between 1.0 and 8.0kHz inclusive.

*2: Default values vary depending on the capacity.

⇒ See the table of K-46.

Sensorless vector/vector with sensor (●:Effective, -:Ineffective)

Sensorless vector/vector with sensor (●:Effective, -:Ineffective)

Sensorless vector/vector with sensor (●:Effective, -:Ineffective)