beautypg.com

Toshiba Tosvert VF-AS1 User Manual

Page 240

background image

K-2

E6581301

11

1. Basic parameter [2/4]

Vector control

Title

Communi

cation

No.

Function

Adjustment range

Minimum

setting unit

(Panel/Communi

cation)

Default

setting

Write during

running

Speed

control

Torque

control

PM

control

V/f

Reference

RV

0015

V/f control mode selection

0:Constant torque characteristics

1:Voltage decrease curve

2:Automatic torque boost

3:Sensorless vector control 1 (speed)

4:Sensorless vector control 2 (speed/torque)

5:V/f 5-point setting

6:PM control

7:PG feedback vector control 1 (speed)

8:PG feedback vector control 2 (speed/torque)

1/1

0

Disabled

-/-

-/-

●/-

●/-

●/-

-/-

-/-

-/●

-/●

-/-

-/-

-/-

-/-

●/-

-/-

-/-

-/-

-/●

-

-

-

-

-

-

-

-

-

-

-

-

-

-

5. 6

XD

0016

Manual torque boost 1

0.0~30.0%

0.1/0.1

*1

Enabled

-

-

5. 7

XN

0014

Base frequency 1

25.0~500.0Hz

0.1/0.01

*3

Disabled

●/●

●/●

5. 8

XNX

0409

Base frequency voltage 1

200V class:50~330V

400V class:50~660V

1/0.1

*1

Disabled

●/●

●/●

5. 8

HJ

0011

Maximum frequency

30.0~500.0Hz

0.1/0.01

80.0

Disabled

●/●

●/●

5. 9

WN

0012

Upper limit frequency

0.0~HJ Hz

0.1/0.01

*3

Enabled

●/●

-

5. 10

NN

0013

Lower limit frequency

0.0~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 10

CEE

0009

Acceleration time 1

0.1~6000 sec.

0.1/0.1 *2

*1

Enabled

●/●

-

5. 2

FGE

0010

Deceleration time 1

0.1~6000 sec.

0.1/0.1 *2

*1

Enabled

●/●

-

5. 2

CXH

0213

RR/S4 input point 2

frequency

0.0~HJ Hz

0.1/0.01

*3

Enabled

●/●

-

5. 11

CKH

0204

VI/II input point 2 frequency 0.0~HJ Hz

0.1/0.01

*3

Enabled

●/●

-

5. 11

UT

0018

Preset speed operation

frequency 1

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

UT

0019

Preset speed operation

frequency 2

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

UT

0020

Preset speed operation

frequency 3

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

UT

0021

Preset speed operation

frequency 4

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

UT

0022

Preset speed operation

frequency 5

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

UT

0023

Preset speed operation

frequency 6

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

UT

0024

Preset speed operation

frequency 7

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

5. 12

HT

0008

Forward run/reverse run

selection (operation panel

operation)

0:Forward run

1:Reverse run

2:Forward run (Forward/reverse switchable on operation

panel)

3:Reverse run (Forward/reverse switchable on operation

panel)

1/1

0

Enabled

●/●

●/●

5. 13

*1: Default values vary depending on the capacity.

⇒ See the table of K-46.

*2: Changing the parameter VR enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).

*3: Inverter with a model number ending with

-WN: 60.0 -WP: 50.0

Sensorless vector/vector with sensor (●:Effective, -:Ineffective)