Toshiba Tosvert VF-AS1 User Manual
Page 248
K-10
E6581301
11
[7] Operation frequency
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f
Reference
H
0240
Starting frequency setting
0.0~10.0Hz
0.1/0.01
0.1
Enabled
●/●
-
●
●
6. 7. 1
H
0241
Operation start frequency
0.0~HJ Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 7. 2
H
0242
Operation start frequency
hysteresis
0.0~30.0Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 7. 2
H
0243
Stop frequency setting
0.0~30.0Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 7. 1
H
0244
Frequency command dead
band
0.0~5.0Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 7. 3
[8] DC braking
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f
Reference
H
0250
DC braking start frequency
0.0~120.0Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 8. 1
H
0251
DC braking current
0~100%
1/1
50
Enabled
●/●
-
●
●
6. 8. 1
H
0252
DC braking time
0.0~20.0 sec.
0.1/0.1
1.0
Enabled
●/●
-
●
●
6. 8. 1
H
0253
Forward/reverse DC braking
priority control
0:OFF, 1:ON
1/1
0
Enabled
●/●
-
●
●
6. 8. 1
H
0254
Motor shaft fixing control
0:Disabled, 1:Enabled
1/1
0
Enabled
●/●
-
●
●
6. 8. 2
H
0255
0Hz command output selection
0:Default (DC braking), 1:0Hz command
1/1
0
Enabled
-/●
-
●
●
6. 8. 3
H
0256
Time limit for lower-limit
frequency operation
0.0:Disabled, 0.1~600.0 sec.
0.1/0.1
0.0
Enabled
●/●
●/●
●
●
6. 9
[9] Jogging operation
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f
Reference
H
0260
Jog run frequency
H
~20.0Hz
0.1/0.01
5.0
Enabled
●/●
-
●
●
6. 10
H
0261
Jog run stop pattern
0:Deceleration stop, 1:Coast stop, 2:DC braking
stop
1/1
0
Disabled
●/●
-
●
●
6. 10
H
0262
Operation panel jog run
operation mode
0:OFF, 1:Operation panel jog run mode enabled
1/1
0
Enabled
●/●
-
●
●
6. 10
H
0264
Input from external contacts -
UP response time
0.0~10.0 sec.
0.1/0.1
0.1
Enabled
●/●
-
●
●
6. 11
H
0265
Input from external contacts -
UP frequency step
0.0~HJ Hz
0.1/0.01
0.1
Enabled
●/●
-
●
●
6. 11
H
0266
Input from external contacts -
DOWN response time
0.0~10.0 sec.
0.1/0.1
0.1
Enabled
●/●
-
●
●
6. 11
H
0267
Input from external contacts -
DOWN frequency step
0.0~HJ Hz
0.1/0.01
0.1
Enabled
●/●
-
●
●
6. 11
H
0268
Initial UP/DOWN frequency
NN
~WN Hz
0.1/0.01
0.0
Enabled
●/●
-
●
●
6. 11
H
0269
Initial up/down frequency
rewriting
0:Not rewrite, 1:Rewrite H when power is
turned off
1/1
1
Enabled
●/●
-
●
●
6. 11
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)