beautypg.com

Toshiba Tosvert VF-AS1 User Manual

Page 248

background image

K-10

E6581301

11

[7] Operation frequency

Vector control

Title

Communi

cation

No.

Function

Adjustment range

Minimum

setting unit

(Panel/Communi

cation)

Default

setting

Write during

running

Speed

control

Torque

control

PM

control

V/f

Reference

H

0240

Starting frequency setting

0.0~10.0Hz

0.1/0.01

0.1

Enabled

●/●

-

6. 7. 1

H

0241

Operation start frequency

0.0~HJ Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 7. 2

H

0242

Operation start frequency

hysteresis

0.0~30.0Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 7. 2

H

0243

Stop frequency setting

0.0~30.0Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 7. 1

H

0244

Frequency command dead

band

0.0~5.0Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 7. 3

[8] DC braking

Vector control

Title

Communi

cation

No.

Function

Adjustment range

Minimum

setting unit

(Panel/Communi

cation)

Default

setting

Write during

running

Speed

control

Torque

control

PM

control

V/f

Reference

H

0250

DC braking start frequency

0.0~120.0Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 8. 1

H

0251

DC braking current

0~100%

1/1

50

Enabled

●/●

-

6. 8. 1

H

0252

DC braking time

0.0~20.0 sec.

0.1/0.1

1.0

Enabled

●/●

-

6. 8. 1

H

0253

Forward/reverse DC braking

priority control

0:OFF, 1:ON

1/1

0

Enabled

●/●

-

6. 8. 1

H

0254

Motor shaft fixing control

0:Disabled, 1:Enabled

1/1

0

Enabled

●/●

-

6. 8. 2

H

0255

0Hz command output selection

0:Default (DC braking), 1:0Hz command

1/1

0

Enabled

-/●

-

6. 8. 3

H

0256

Time limit for lower-limit

frequency operation

0.0:Disabled, 0.1~600.0 sec.

0.1/0.1

0.0

Enabled

●/●

●/●

6. 9

[9] Jogging operation

Vector control

Title

Communi

cation

No.

Function

Adjustment range

Minimum

setting unit

(Panel/Communi

cation)

Default

setting

Write during

running

Speed

control

Torque

control

PM

control

V/f

Reference

H

0260

Jog run frequency

H

~20.0Hz

0.1/0.01

5.0

Enabled

●/●

-

6. 10

H

0261

Jog run stop pattern

0:Deceleration stop, 1:Coast stop, 2:DC braking

stop

1/1

0

Disabled

●/●

-

6. 10

H

0262

Operation panel jog run

operation mode

0:OFF, 1:Operation panel jog run mode enabled

1/1

0

Enabled

●/●

-

6. 10

H

0264

Input from external contacts -

UP response time

0.0~10.0 sec.

0.1/0.1

0.1

Enabled

●/●

-

6. 11

H

0265

Input from external contacts -

UP frequency step

0.0~HJ Hz

0.1/0.01

0.1

Enabled

●/●

-

6. 11

H

0266

Input from external contacts -

DOWN response time

0.0~10.0 sec.

0.1/0.1

0.1

Enabled

●/●

-

6. 11

H

0267

Input from external contacts -

DOWN frequency step

0.0~HJ Hz

0.1/0.01

0.1

Enabled

●/●

-

6. 11

H

0268

Initial UP/DOWN frequency

NN

~WN Hz

0.1/0.01

0.0

Enabled

●/●

-

6. 11

H

0269

Initial up/down frequency

rewriting

0:Not rewrite, 1:Rewrite H when power is

turned off

1/1

1

Enabled

●/●

-

6. 11

Sensorless vector/vector with sensor (●:Effective, -:Ineffective)

Sensorless vector/vector with sensor (●:Effective, -:Ineffective)

Sensorless vector/vector with sensor (●:Effective, -:Ineffective)