Page 268

background image

K-30

E6581301

11

[28] Communication function [2/4]

Vector control

Title

Communi

cation

No.

Function

Adjustment range

Minimum

setting unit

(Panel/Communi

cation)

Default

setting

Write during

running

Speed

control

Torque

control

PM

control V/f Constant Reference

H

0826

Inverter-to-inverter

communication setting (4-wire

RS485)

0:Slave (issues a 0Hz command if something goes

wrong with the master)

1:Slave (continues operation if something goes

wrong with the master)

2:Slave (trips for emergency stop if something

goes wrong with the master)

3:Master (sends a frequency command)

4:Master (sends an output frequency)

5:Master (sends a torque command)

6:Master (sends an output torque command)

1/1

0

Enabled

●/●

●/●

6. 38. 1

H

0829

Protocol selection (4-wire

RS485)

0:TOSHIBA

1:MODBUS

1/1

0

Enabled

●/●

●/●

6. 38. 1

H

0830

Communication option

(DeviceNet/ PROFIBUS) setting 1 0~7

1/1

0

Enabled

●/●

●/●

*1

H

0831

Communication option

(DeviceNet/ PROFIBUS) setting 2 0000~

HHHH

1/1

0000

Enabled

●/●

●/●

*1

H

0832

Communication option

(DeviceNet/ PROFIBUS) setting 3 0000~

HHHH

1/1

0000

Enabled

●/●

●/●

*1

H

0833

Communication option

(DeviceNet/ PROFIBUS) setting 4 0000~

HHHH

1/1

0000

Enabled

●/●

●/●

*1

H

0834

Communication option

(DeviceNet/ PROFIBUS) setting 5 0000~

HHHH

1/1

0000

Enabled

●/●

●/●

*1

H

0835

Communication option

(DeviceNet/ PROFIBUS) setting 6 0000~

HHHH

1/1

0000

Enabled

●/●

●/●

*1

H

0836

Communication option

(DeviceNet/ PROFIBUS) setting 7 0000~

HHHH

1/1

0000

Enabled

●/●

●/●

*1

H

0841

Communication option

(DeviceNet/ PROFIBUS) setting 8 0000~

HHHH

1/1

0000

Enabled

●/●

●/●

*1

H

0842

Communication option

(DeviceNet/ PROFIBUS) setting 9 0000~

HHHH

1/1

0000

Enabled

●/●

●/●

*1

H

0843

Communication option (DeviceNet/

PROFIBUS) setting 10

0000~HHHH

1/1

0000

Enabled

●/●

●/●

*1

H

0844

Communication option (DeviceNet/

PROFIBUS) setting 11

0000~HHHH

1/1

0000

Enabled

●/●

●/●

*1

*1:

⇒ For details, refer to Instruction Manual (E6581281, E6581343) specified in Section 6.41.

Sensorless vector/vector with sensor (●:Effective, -:Ineffective)