6

6.30

Acceleration/deceleration 2

6.30.1 Setting acceleration/deceleration patterns and switching

acceleration/deceleration patterns 1, 2, 3 and 4

H

: Acceleration time 2

H

: Deceleration time 2

H

: Acceleration/deceleration 1 pattern

H

: Acceleration/deceleration 2 pattern

H

: Acceleration/deceleration time 1, 2, 3, 4 selection

H

: Acceleration/deceleration switching frequency 1

H

: Acceleration S-pattern lower limit adjustment

H

: Acceleration S-pattern upper limit adjustment

H

: Deceleration S-pattern lower limit adjustment

H

: Deceleration S-pattern upper limit adjustment

H

: Acceleration time 3

H

: Deceleration time 3

H

: Acceleration/deceleration 3 pattern

H

: Acceleration/deceleration switching frequency 2

H

: Acceleration time 4

H

: Deceleration time 4

H

: Acceleration/deceleration 4 pattern

H

: Acceleration/deceleration switching frequency 3

• Function

Four acceleration times and four deceleration times can be specified individually. The selection/switching
mode can be selected from the following 3 options:

1) Selection by means of parameters
2) Switching by means of frequencies
3) Switching by means of terminals

[Parameter setting]

Title

Function

Adjustment range

Default setting

H

Acceleration time 2

[Note]~ sec.

According to model

H

Deceleration time 2

[Note]~ sec.

According to model

H

Acceleration/deceleration 1, 2, 3,
4 selection

:Acceleration/deceleration 1,

: Acceleration/deceleration 2,

: Acceleration/deceleration 3,

: Acceleration/deceleration 4

H

Acceleration time 3

[Note]~ sec.

According to model

H

Deceleration time 3

[Note]~ sec.

According to model

H

Acceleration time 4

[Note]~ sec.

According to model

H

Deceleration time 4

[Note]~ sec.

According to model

Note:The minimum setting of acceleration and deceleration times have been set respectively at 0.1 sec. by default,

but they can be changed within a range of 0.01 sec. (setting range:0.01~600.0 sec.) by changing the setting of
the parameter V[R (default setting).
⇒ For details, refer to Section 5.20.

1) Selection using parameters

Time [s]

Output frequency [Hz]

FGE

CEE

HJ

H

H

H

H

H

H

0

Time [s]

Time [s]

Time [s]

H

=

H

=

H

=

H

=

Acceleration/deceleration time 1 is initially set as the default. Acceleration/deceleration time 2, 3 and 4can be
selected by changing the setting of the H.
Enabled if EOQF= (operation panel input enabled).