Toshiba Tosvert VF-AS1 User Manual
Page 278
K-40
E6581301
11
[Monitor FM/AM/pulse output function selection (2/2)]
Sensorless vector/vector with sensor (●: valid, -: invalid)
FM/AM/pulse output
Monitor output
Option No. Communicati
on No.
Option No. Communicati
on No.
Function
Unit
(Communicat
ion)
Trip retention
Speed control
Torque control
PM control
V/f
Reference
-
-
33
FE67
Attached to expansion I/O card 2 CPU
version
-
×
●/●
●/●
●
●
34
FE76
34
FE76
Integral input power
0.01kW
×
●/●
●/●
●
●
35
FE77
35
FE77
Integral output power
0.01kW
×
●/●
●/●
●
●
45
0006 *3
0671 *4
-
-
Gain display
1
-
●/●
●/●
●
●
46
FE60
-
-
My function monitor 1 (Output of
unsigned value)
1
×
●/●
●/●
●
●
47
FE61
-
-
My function monitor 2 (Output of
unsigned value)
1
×
●/●
●/●
●
●
48
FE62
-
-
My function monitor 3 (Output of signed
value) *2
1
×
●/●
●/●
●
●
49
FE63
-
-
My function monitor 4 (Output of signed
value) *2
1
×
●/●
●/●
●
●
50
FD00
50
FE00
Signed output frequency
-
○
●/●
●/●
●
●
51
FD02
51
FE02
Signed frequency command value
-
○
●/●
-
●
●
52
FD15
52
FE15
Signed compensated frequency
-
○
●/●
●/●
●
●
53
FD16
53
FE16
Signed speed feedback (real-time value)
-
○
-/●
-/●
-
-
54
FD17
54
FE17
Signed speed feedback (1-second filter)
-
○
-/●
-/●
-
-
55
FD18
55
FE18
Signed torque
-
○
●/●
●/●
●
●*1
56
FD19
56
FE19
Signed torque command
-
○
-
●/●
-
-
58
FD20
58
FE20
Signed torque current
-
○
●/●
●/●
-
● *1
59
FD22
59
FE22
Signed PID feedback value
-
○
●/●
-
●
●
60
FE37
60
FE37
Signed RX input
-
×
●/●
●/●
●
●
61
FE38
61
FE38
Signed optional AI1 input
-
×
●/●
●/●
●
●
62
FE51
-
-
Signed fixed output 1
-
×
●/●
●/●
●
●
63
FE50
-
-
Signed fixed output 2
-
×
●/●
●/●
●
●
64
FE52
-
-
Signed fixed output 3
-
×
●/●
●/●
●
●
-
-
64
FD50
Light-load high-speed load torque monitor 1
0.01%
×
●/●
●/●
●
●
-
-
65
FD51
Light-load high-speed load torque monitor 2
0.01%
×
●/●
●/●
●
●
-
-
66
FE31
Pattern operation group number
0.1
×
●/●
-
●
●
-
-
67
FE32
Remaining no. of cycles for which pattern
operation is continued
1
×
●/●
-
●
●
-
-
68
FE33
Pattern operation preset speed numbers
1
×
●/●
-
●
●
-
-
69
FE34
Remaining time for which pattern
operation is continued
0.1
×
●/●
-
●
●
-
-
70
FE84
16-bit BIN/BCD input value
1
○
●/●
●/●
●
●
5.16
8.3
*1: Reference data *2: An absolute value is output for pulse train output of 48 and 49.
*3: Communication no. for FM output
*4: Communication no. for AM output
⇒ For details, refer to Section 5.16; [Terminal FM-related parameters].
⇒ For monitor indications, refer to Section 8.3; [Set up values of monitor indication parameters].