Rx cca, Vi/ii cca – Toshiba Tosvert VF-AS1 User Manual
Page 59

E6581301
C-5
3
4) Setting the frequency using input voltage (0~10Vdc)
[Parameter setting]
5) Setting the frequency using input voltage (0~±10Vdc)
The direction can be changed by switching between positive and negative signals.
[Parameter setting]
Set the “basic parameter frequency setting mode selection 1” parameter
HOQF to .
Note: Set reference frequency priority selection H to (HOQF/H terminal switching, default setting).
Changing the settings of two speed command parameters at a time, refer to Section 6.6.
[Example of setting: To set the frequency by applying a current of 4(0)-20mAdc via the VI/II terminal.]
Key operated
LED display
Operation
Displays the operation frequency. (Perform during operation stopped.)
(When standard monitor display selection H=[Output
frequency])
CWJ
Displays the first basic parameter “History function (CWJ).”
HOQF
Press either the or key to select “HOQF.”
Press the ENTER key to display the parameter setting (Default
setting:).
Press the key to change the parameter to .
⇔HOQF
Press the ENTER key to save the changed parameter. HOQF and the
parameter are displayed alternately.
MODE
Frequency
0
0Vdc
10Vdc
60Hz
Set the “extended parameter analog input VI/II voltage/current switching”
parameter HOQF to .
In addition, set the “basic parameter frequency setting mode selection 1” parameter
H
to (default setting
)
.
+
-
RX
CCA
-10Vdc
+10Vdc
Forward run
Reverse run
60Hz
60Hz
+
-
ENT
ENT
VI/II
CCA
+
Voltage signal
Voltage signal (0~10V) for setting the operation frequency
⇒ Refer to Section 7.3 for details of adjustment.
:Voltage signal 0-10Vdc
+
Voltage signal
Voltage signal (0~±10V) for setting the operation frequency
⇒ Refer to Section 7.3 for details of adjustment.
:Voltage signal 0-±10Vdc