beautypg.com

25 torque limit – Toshiba Tosvert VF-AS1 User Manual

Page 154

background image

E6581301

F-42

6

6.25

Torque limit

6.25.1 Torque limit switching

H

: Power running torque limit 1

selection

H

: Power running torque limit 1

level

H

: Regenerative braking torque

limit 1 selection

H

: Regenerative braking torque

limit 1 level

H

: Power running torque limit 2

level

H

: Regenerative braking torque

limit 2 level

H

: Power running torque limit 3

level

H

: Regenerative braking torque

limit 3 level

H

: Power running torque limit 4

level

H

: Regenerative braking torque

limit 4 level

Function

This function is to decrease or increase the output frequency according to the loading condition when the
motor torque reaches the limit level. Setting a torque limit parameter at 250% means “Invalid.”

Setting methods

(1) When setting limits to torque, use internal parameters (Torque limits can also be set with an external control

device.)

+250% torque

-250% torque

Power
running

Regenerative

Forward run

H

H

Regenerative

Power
running

H

H

Positive torque

Negative torque

Reverse run

Torque limits can be set with the parameters H and H.
[Setting of power running torque]

H

(Power running torque limit 1 selection)

: Set at (H)

H

(Power running torque limit 1)

: Set a desirable torque limit level.

[Setting of regenerative torque]

H

(Regenerative braking torque limit 1 selection) : Set at (H)

H

(Regenerative braking torque limit 1)

: Set a desirable torque limit level.