[29] My function [4/5]
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
H
0948
Input function command 61
Same as H
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0949
Input function target 62
Same as H
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0950
Input function command 62
Same as H
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0951
Input function target 63
Same as H
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0952
Output function assigned object
6
Same as H
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0953
Input function target 71
Same as H
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0954
Input function command 71
Same as H
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0955
Input function target 72
Same as H
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0956
Input function command 72
Same as H
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0957
Input function target 73
Same as H
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0958
Output function assigned object
7
Same as H
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0959
Analog input function target 11
0:Deselect
1:VI/II
2:RR/S4
3:RX
4:Optional AI1+, Optional AI1-
5:Optional AI2
1/1
0
Enabled
●/●
●/●
●
●
*1
H
0961
Analog function assigned object
11
0:Disabled
1: Acceleration
2: Upper limit frequency (WN)
3:Acceleration multiplication factor
4:Deceleration multiplication factor
5: Manual torque boost (XD)
6:OC stall (H)
7:Thermal protection (VJT)
8:Speed loop P gain (H)
9:Drooping gain (H)
10:PID P gain (H)
1/1
0
Disabled
●/●
●/●
●
●