Toshiba Tosvert VF-AS1 User Manual
Page 149

E6581301
F-37
6
Here are the use conditions.
Motor used
Type
No. of motor poles
Capacity
Auto-tuning 1 setting
Same as the inverter capacity
* Not required (tuned to factory defaults)
4P
Different from the inverter capacity
Same as the inverter capacity
Toshiba
standard
motor
Other than 4P
Different from the inverter capacity
Others
Required
* When using a long cable (guide: 30m or over), be sure to make auto-tuning 1 (H=).
Set H at
Toshiba standard 4P motor
GVP
is displayed.
The base frequency or the rated
rotational speed of the motor is
not set correctly. Check their
settings.
Enter the correct value for XN
or H, and then set H
to again.
Set the following parameters, as specified on
the motor nameplate.
Nameplate
information
Title
Setting range
Base frequency XN
~Hz
Base frequency
voltage
XNX
~ (200V)
~ (400V)
Rated capacity
of motor
H ~kw
Motor rated
current
H ~A
Motor rated
speed
H
~
min-1
The following parameters have
been calculated and set.
H
Motor constant 1
H
Motor constant 2
H
Motor constant 3
H
Motor constant 4
Enter the rated capacity of the
motor, using H
End
Is motor capacity same
with inverter capacity?
Set H at
End
YES
NO
NO
YES
NO
YES
H
and H have been
tuned to the motor connected.
Set H to and start
operation.
Parameters H and
H
use the value calculated
automatically by the inverter.
End
GPV
or
GPV
is displayed.
End
YES
NO