beautypg.com

Toshiba Tosvert VF-AS1 User Manual

Page 153

background image

E6581301

F-41

6

For a crane/hoist, an elevator application, as lifted
up and down at controlled speeds, the direction of
rotation is frequently reversed. In such cases, the
load can be started smoothly, by adding load
torque into the torque reference equivalent to the
additional torque, when starting acceleration after
releasing the brake.

[Selection of external signals]

2) Selection of tension torque bias input and load sharing gain input

Torque reference

Torque command

+

Tension torque bias

Load sharing gain

×

+

+

[Parameter setting]

Title

Function

Adjustment range

Default setting

H

Tension torque bias input
selection

:Disabled

:VI/II (voltage/current input)

:RR/S4 (potentiometer/voltage input)

:RX (voltage input)

:Operation panel input enabled (including

LED/LCD option input)

:2-wire RS485 input enabled

:4-wire RS485 input enabled

:Communication option input enabled

:Optional AI1 (Differential current input)

H

Control panel tension torque bias

~%

H

Load sharing gain selection

:Disabled

:VI/II (voltage/current input)

:RR/S4 (potentiometer/voltage input)

:RX (voltage input)

:Operation panel input enabled (including

LED/LCD option input)

:2-wire RS485 input enabled

:4-wire RS485 input enabled

:Communication option input enabled

:Optional AI1 (Differential current input)

H

Control panel load sharing gain

~%

[Selection of external signals]

H

, H

RR/S4-CC – 0~10V

(0~250%)

RX-CC – 0~±10V

(-250~250%)

VI/II-CC – 0~10V

(0~250%)

VI/II-CC – 4(0)20m

(0~250%)

Voltage signals

Current signals

H

RR/S4-CC – 0~10V

(0~250%)

RX-CC – 0~±10V

(-250~250%)

VI/II-CC – 0~10V

(0~250%)

VI/II-CC – 4(0)~20mA

(0~250%)

Voltage signals

Current signals

Additional torque
(fixed direction)

Reverse run

Forward run

Tension torque bias
as additional torque