Toshiba Tosvert VF-AS1 User Manual

Page 269

background image

K-31

E6581301

11

[28] Communication function [3/4]

Vector control

Title

Communi

cation

No.

Function

Adjustment range

Minimum

setting unit

(Panel/Communi

cation)

Default

setting

Write during

running

Speed

control

Torque

control

PM

control V/f Constant Reference

H

0845

Communication option (DeviceNet/

PROFIBUS) setting 12

0000~HHHH

1/1

0000

Enabled

●/●

●/●

*1

H

0846

Communication option (DeviceNet/

PROFIBUS) setting 13

0000~HHHH

1/1

0000

Enabled

●/●

●/●

*1

H

0850

Disconnection detection

extended time

0.0~100.0 sec.

0.1/0.1

0.0

Enabled

●/●

●/●

*1

H

0851

Inverter operation at

disconnection

0:Inverter stop, communication command,

frequency mode open (by EOQF, HOQF)

1:None (continued operation)

2:Deceleration stop

3:Coast stop

4:Network error (GTT trip)

5:Preset speed operation (by H setting)

1/1

0

Enabled

●/●

●/●

*1

H

0852

Preset speed operation

selection

0:None

1~15:Preset speed operation (by parameter

setting)

1/1

0

Enabled

●/●

●/●

*1

H

0853

Communication option station

address monitor

0~255

1/1

0

Enabled

●/●

●/●

*2

H

0854

Communication option speed

switch monitor

DeviceNet/CC-Link

0~255

1/1

0

Enabled

●/●

●/●

*2

H

0870

Block write data 1

0:Deselect

1:Command information 1

2:Command information 2

3:Frequency command

4:Terminal board output data

5:Communication analog data

1/1

0

Enabled

●/●

●/●

6. 38. 1

H

0871

Block write data 2

Ditto

1/1

0

Enabled

●/●

●/●

6. 38. 1

*1:

⇒ For details, refer to Instruction Manual (E6581281, E6581343) specified in Section 6.41.

*2:

⇒ For details, refer to Instruction Manual (E6581281, E6581343, E6581288) specified in Section 6.41.

Sensorless vector/vector with sensor (●:Effective, -:Ineffective)