beautypg.com

Basic parameters, 1 history function – Toshiba Tosvert VF-AS1 User Manual

Page 67

background image

E6581301

E-1

5

5. Basic parameters

This parameter is a basic parameter for the operation of the inverter.
⇒ Refer to Section 11, Table of parameters.

5.1

History function

CWJ

: History function

Note 1: If no history information is stored, this parameter is skipped and the next parameter CW.
Note 2: JGCF and GPF are added respectively to the first and last parameters in a history of changes.

[Setting methods]

Key operated

LED display

Operation

Displays the operation frequency (operation stopped).
(When standard monitor display selection H=
[Output frequency])

CWJ

The first basic parameter “History function (CWJ)” is
displayed.

CEE

The parameter that was set or changed last is displayed.

Press the ENTER key to display the set value.

Press the key and key to change set value.

⇔CEE

Press the ENTER key to save the changed value. The
parameter name and the programmed value will flash on
and off alternately.

( )

****

Use the same steps as those given above to display
parameters that you want to search for or change setting
with the key and key.

( )

JGCF

(GPF)

JGCF

: First historic record

GPF

: Last historic record

Parameter display

CWJ

HTH

Press the MODE key to return to the parameter setting
mode CWJ.
After that you can press the MODE key to return to the
status monitor mode or the standard monitor mode (display
of operation frequency).

• Function

Automatically searches for 5 latest parameters that are programmed with values different from
the standard default setting and displays them in the CWJ. Parameter setting can also be
changed within this group CWJ.
This function comes in very handy when you adjust the inverter repeatedly using the same
parameter.

MODE

ENT

ENT

ENT

MODE

MODE

MODE