E6581301

F-18

6

6.9

Auto-stop in case of lower-limit frequency continuous operation

H

: Time limit for lower-limit frequency operation

• Function

If operation is carried out continuously at a frequency below the lower-limit frequency (NN) for the period
time set H, theinverter will automatically slow down the motor to a stop.
“NUVR” is always displayed on the operation panel. (Blinking alternately)
The auto-stop function will be disabled when the frequency command value reaches over the lower limit
frequency (NN)+0.2Hz or the operation command is turned to off.

[Parameter setting]

Title

Function

Adjustment range

Default setting

H

Auto-stop in case of lower-limit frequency
continuous operation

:None

~ sec.

Output frequency [Hz]

H

H

H

Time [s]

Operation signal (F-CC)

ON

OFF

NN

+0.2Hz

NN

Note:This function is enabled even at the start of operation and during switching between forward and reverse run.