4 setting parameters by operating method – Toshiba Tosvert VF-AS1 User Manual
Page 71
E6581301
E-5
5
5.4
Setting parameters by operating method
CW
: Automatic function setting
[Parameter setting]
Title
Function
Adjustment range
Default setting
CW
Automatic function setting
:Disabled
:Frequency setting by means of voltage
:Frequency setting by means of current
:Voltage/current switching from external
terminal
: Frequency setting on operation panel and
operation by means of terminal
: Frequency setting and operation on
operation panel
Automatically programmed functions and parameter set values
Default
setting
:Disabled
:Frequency
setting by
means of
voltage
:Frequency
setting by
means of
current
:Voltage/current
switching from
external
terminal
: Frequency
setting on
operation panel
and operation
by means of
terminal
: Frequency
setting and
operation on
operation panel
EOF
:Terminal
board
–
–
–
–
:Terminal board :Operation panel
HOF
:RR/S4
–
:RR/S4
:VI/II
:RR/S4
:Operation
panel
:Operation
panel
H
:V
–
–
:I
:I
–
–
H
(S3)
:
Preset
speed
command
3
–
–
–
:Frequency
priority switching
–
–
H
:HOF
/H
terminal
switching
–
:HOF/
H
terminal
switching
:HOF/
H
terminal
switching
:HOF/
H
terminal
switching
:HOF/
H
terminal
switching
:HOF/
H
terminal
switching
H
%
–
–
%
%
–
–
H
:VI/II
–
:RR/S4
:VI/II
:VI/II
:Operation
panel
:Operation
panel
⇒ Refer to Section 11 for input terminal functions.
No change is made to the parameter setting.
Operation is performed by applying a voltage for setting the RR/S4 terminal 1 frequency.
When sink logic is selected:
ST-CC ON: Standby (ON (short-circuited) by default)
F-CC ON: Forward run
R-CC ON: Reverse run
This setting is used to set the frequency by applying a current of 4-20mA to the VI/II terminal.
ST-CC ON: Standby (ON (short-circuited) by default)
F-CC ON: Forward run
R-CC ON: Reverse run
• Function
Automatically programs all parameters (parameters described below) related to the functions by
selecting the inverter's operating method.
The major functions can be programmed simply.
Inoperative (CW=)
Frequency setting by means of voltage: (CW=)
Frequency setting by means of current (CW=)