Trinix NXT — Installation and Service Manual

Section 2 — Planning Guide

Figure 46. 512 x 512 System Expanded to 1024 x 512

Frame 1 contains no input or output boards, but the wiring has already
been installed between Frame 1 and the PE-331016 Port expanders.

Now consider Output 1 of Frame 0. This signal is connected to Input 1A of
the first PE-33016 Port expander. See

Figure 47

below.

Figure 47. Detail of One PE-33016

In this example:

Only Input 1A and Output 1A are presently functional.

Output 1B is fitted with a 75-ohm BNC terminator, which is following
the rule that unused connectors should be terminated.

Input 1B is pre-wired to Frame 1, so there is no place for a terminator.
In this case, termination will be provided by an LD-33100 Loader board,
which has been installed in output board slot 1-32 of Frame 0. Further-
more, in this example all 16 output slots of Frame 0 should have an LD-
33000 installed.

When the system is upgraded to 1024 x 512, the LD-33000 boards will
be removed and replaced by output boards. The cabling to the port
expanders is already in place.

Frame 0

Trinix

512 x 512

1 - 512

1 - 512

Future input
wiring

1 - 512

outputs

32

PE 33016

used as

combiners

Trinix

512 x 512

Frame 1

(unused)

Installed pre-wiring

Output slots should be terminated
using LD-33100 Loader boards

Input 1B - from Frame 1 Output 1.

Input 1A - from Frame 0 Output 1

Output 1A - to downstream equipment

Output 1B - not used. Termination provided by

Termination provided by LD-33000

75-ohm BNC terminator

in upstream Trinix frame.