beautypg.com

Trinix asymmetrical frames, Legend – Grass Valley Trinix NXT v.3.3.1 User Manual

Page 210

background image

210

Trinix NXT — Installation and Service Manual

Section 3 — Hardware Installation

In systems controlled by SR-33000 boards, Monitor Expansion jumpers JN3
and JN4 on the SR-33000 boards must be set to “Exp.”

Note

Output monitoring is not available for input-expanded systems controlled by
an SR-33000 Sync/OPM board.

Trinix Asymmetrical Frames

In expanded systems, output monitors are cascaded from expanded frames
to the main frame via the TRX-SR for the 256x512 and the TRX-OPM for the
128x256, and 512x1024 output monitor inputs. See

Figure 115 on page 202

for Monitoring connection locations.

Expansion of two 128x256 Asymmetrical frames to form a 256x256 with
output monitoring. There will be missing ports in the inputs that will need
to be adjusted in the Control system.

Figure 120. Expanded Trinix 128x256 Asymmetrical Frames with Output Monitoring

Trinix

NXT

128x256
Switcher

Frame 0

16 ea.

16x2:2

COMBINERS

Outputs 1-256

Outputs 1-256

Outputs 1-256

Inputs 1-128

Inputs 129-257

Trinix

NXT

128x256
Switcher

Frame 1

CAS ins (4)

MON outs (4)

MON outs (4)

CAS ins (4)

No Connect

Or Test Signal

Note: The order of the

frames for the monitor

cascade does not matter.

4 75 ohm coaxial cables

MON outs (4)

System Outs

(Outputs 257-260)

071827611_expansion_2_frame-256^2_woutput-mon