Trinix asymmetrical frames, Legend – Grass Valley Trinix NXT v.3.3.1 User Manual
Page 210
210
Trinix NXT — Installation and Service Manual
Section 3 — Hardware Installation
In systems controlled by SR-33000 boards, Monitor Expansion jumpers JN3
and JN4 on the SR-33000 boards must be set to “Exp.”
Note
Output monitoring is not available for input-expanded systems controlled by
an SR-33000 Sync/OPM board.
Trinix Asymmetrical Frames
In expanded systems, output monitors are cascaded from expanded frames
to the main frame via the TRX-SR for the 256x512 and the TRX-OPM for the
128x256, and 512x1024 output monitor inputs. See
for Monitoring connection locations.
Expansion of two 128x256 Asymmetrical frames to form a 256x256 with
output monitoring. There will be missing ports in the inputs that will need
to be adjusted in the Control system.
Figure 120. Expanded Trinix 128x256 Asymmetrical Frames with Output Monitoring
Trinix
NXT
128x256
Switcher
Frame 0
16 ea.
16x2:2
COMBINERS
Outputs 1-256
Outputs 1-256
Outputs 1-256
Inputs 1-128
Inputs 129-257
Trinix
NXT
128x256
Switcher
Frame 1
CAS ins (4)
MON outs (4)
MON outs (4)
CAS ins (4)
No Connect
Or Test Signal
Note: The order of the
frames for the monitor
cascade does not matter.
4 75 ohm coaxial cables
MON outs (4)
System Outs
(Outputs 257-260)
071827611_expansion_2_frame-256^2_woutput-mon
Legend:
CAS = Cascade
MON =
Monitor
Ins = Inputs
Outs = Outputs