Fuse differences, Power supplies for trx-nxt-512x512 – Grass Valley Trinix NXT v.3.3.1 User Manual
Page 127
Installation and Service Manual127
Note
For more information about Power Supply connections with Asymmetric
frames, see Trinix Asymmetrical Power Supply Configurations
. Grass Valley strongly recommends, whenever possible, using
the AC high line to reduce line currents and heat within the power sup-
plies.
The following items should be considered during the installation pro-
cess.
Fuse Differences
Make sure that you use the correct fuse when you change from 120Vac
to 220Vac. There is a fuse difference on the rear panel of the 128 x 128,
the 256 x 256, and the 512 x 512 frames.
Note
See the markings on the router’s rear panel frame for the correct Fuse
value requirements.
For additional power supply information, see Power Supply Notes
Asymmetric Frames
For fuse information in the Asymmetrical frames, see Trinix Asymmet-
rical Power Supply Configurations
.
Power Supplies for TRX-NXT-512x512
Power supplies for TRX-NXT-512x512 Routing switchers are mounted
in a separate frame.
•
You will need to attach the supplied cable from the DC
Output connector on the power supply frame to the DC
Input connector on the Routing switcher’s frame.
•
The power supply for the TRX-NXT-512x512 frames may be
mounted above or below the main frame, depending on the
video cable routing and weight distribution requirements.
Using IFC cables with the TRX-NXT-512x512
CAUTION In order to avoid damaging the Routing switcher, the power must be
turned OFF before installing the “IFC” cables as described in the fol-
lowing step.