Grass Valley Trinix NXT v.3.3.1 User Manual
Page 130
130
Trinix NXT — Installation and Service Manual
Section 3 — Hardware Installation
4.
On High Definition and 3G Routing switchers:
a.
The Signal reclocking mode can be set for each output on an output
board. Auto is the factory default setting.
•
This setting means that properly-formed standard data-rate
signals will be reclocked. Other signals will be bypassed or not
reclocked. See Output Reclocker Bypass Settings
for
details.
This reclocking feature is not included with SD Routing switchers
do not include the reclocking feature.
Configuring Each Output Monitor on the TRX-OPM Boards
The Sync selection setting of each output monitor on the TRX-OPM
boards is provided in
. The TRX-OPM boards are in the
128x256 and 512x1024 frame only. The DIP Switch that is to be con-
figured is located on the rear side, near the bottom, of the TRX-OPM
board.
The settings are the same as a standard Trinix Output VIT selection
switch. Code 00 (off, off) thru code 11 (on, on) selects the first thru
the fourth reference input, respectively, for the preferred output.
Table 24. OPM DIP- Switch Settings
Switch
Description
S1-1
Least Significant Bit (LSB) of reference source used for Moni-
tor Output 1
S1-2
Most Significant Bit (MSB) of reference source used for Moni-
tor Output 1
S1-3
LSB of reference source used for Monitor Output 2
S1-4
MSB of reference source used for Monitor Output 2
S1-5
LSB of reference source used for Monitor Output 3
S1-6
MSB of reference source used for Monitor Output 3
S1-7
LSB of reference source used for Monitor Output 4
S1-8