Asymmetrical frames – Grass Valley Trinix NXT v.3.3.1 User Manual
Page 104

104
Trinix NXT — Installation and Service Manual
Section 2 — Planning Guide
Asymmetrical Frames
When Using the Protected Paths feature with the Asymmetrical frames,
you will be able to protect half the outputs but those protected outputs
cannot be greater than half the number of inputs. For example, the 128x256
router:
•
Outputs 0 – 127 (1-128) could protect outputs 128 - 255 (129-256) but
only 64 of these outputs.
That means:
•
Outputs 0 – 63 (1-64) could protect outputs 128 – 191 (129 – 192)
•
or Outputs 64 – 127 (65 – 128) could protect outputs 192 – 255 (193 –
256).
TRX-NXT-128x256
Recommended Protected path ranges for TRX-NXT-128x256 routers are as
follows:
TRX-NXT-256x512
Recommended Protected path ranges for TRX-NXT-256x512 routers are as
follows:
TRX-NXT-512x1024
Recommended Protected path ranges for TRX-NXT-512x1024 routers are as
follows:
Table 13. Recommended Protected Path Ranges
Primary Path
Secondary Path
Out
In
Out
In
1-64
1-64
65-128
65-128
Table 14. Recommended Protected Path Ranges
Primary Path
Secondary Path
Out
In
Out
In
1-128
1-128
129-256
129-256
Table 15. Recommended Protected Path Ranges
Primary Path
Secondary Path
Out
In
Out
In
1-256
1-256
513-769
257-512