Trinix NXT — Installation and Service Manual

Section 4 — Trinix Asymmetrical Power Supply Configurations

Basic Configuration for the Lineage Power Supply Frame

The basic power supply frame’s configuration (

Figure 137

) consists of the

following:

A Power Supply frame.

A 10 ft. (3.05 meters) Trinix Power Supply cable.

A 10 ft. (3.05 meters) Trinix Power Supply interface cable.

The GV part # for the basic configuration assembly is 751-0326-00.

Figure 137. Lineage Power Supply Frame Basic Configuration

Trinix Asymmetrical Frames

The Trinix Asymmetrical frames are designed to interact and communicate
with an external power supply frame. The Asymmetrical frames provide
isolated power input connectors and includes one or more TRX-SC boards
for power supply monitoring. The number of power connectors and TRX-
SC boards will vary depending on the Asymmetrical router size. Each
Asymmetrical router will support multiple redundant power supply con-
figurations.

Each Asymmetrical power supply frame and the possible redundant
power supply configurations are covered in the following sections.

Trinix Status Concentrator Board (TRX-SC)

The TRX-SC board is used for the Trinix Power-Supply Rack frame to com-
municate with the Trinix Asymmetrical routing switcher. Each TRX-SC
board provides two I

2

C interface connectors that will monitor and provide

the status of the external power supply modules. Each TRX-SC board must

071827609_Trinix-PS

-Rack_rearview

The Power Supply
cable

The Power Supply
frame

The power
supply’s interface

This manual is related to the following products: