Specifications

128 x 256 frame: 25.0 A

256 x 512 frame: 25.0 A

512 x1024 frame: 25.0 A

Hold-up Time:

Minimum 15 ms at full load

Conducted Emissions:

per FCC Class B, EN55022 Class B

Power Supply DC Output

Voltage:

+48

(+/-0.5)

VDC

Current:

128 x 128 frame: 20 A/supply (full redundancy)
256 x 256 frame: 26 A/supply (full redundancy)
512 x 512 frame: approximately. 26 A/supply (full redundancy)
128x256 frame: 25 A/ supply (full redundancy)

256x512 frame: 25 A/ supply (full redundancy)

512x1024 frame: 25 A/ supply (full redundancy)

Note

The 256 x 256 and the 512 x 512 routing frames use the same power supply.
All Asymmetrical frames use the same power supply

Current Sharing:

Yes, maximum 20% differential unbalance

Ripple/Noise:

<500 mVp-p

DC Power Input

Input voltage Range

42-54 VDC +/- 0%

Operating Current

The Operating current will vary depending on the specific con-
figuration of the router. The two cases below will serve as a ref-
erence.

CASE A: A fully configured system

DV-33128 and NXT-128

12 A @ 48 VDC

DV-33256 and NXT-256

23 A @ 48 VDC

DV-33512 and NXT-512

46 A @ 48 VDC

TRX-NXT-128x256

21 A @ 48 VDC

TRX-NXT-256x512

42 A @ 48 VDC

TRX-NXT-512x1024