Trinix NXT — Installation and Service Manual
235
The 128X256 Trinix Asymmetrical Frame
The 128X256 Redundant Power Supply Configurations - A and B Option
The A and B configuration options for the redundant power supply
includes the Trinix default power supply configuration and one or two
additional power supply modules (see
and
).
The power is connected to the DC INPUT A connector on the router frame.
The power supply’s interface cable is connected to the PMBUS A connector
on the router frame.
Figure 144. Trinix 128X256 Redundant PSU Configurations, Options A
The option A configuration uses one power supply and three power supply
modules.