beautypg.com

Grass Valley Trinix NXT v.3.3.1 User Manual

Page 107

background image

Trinix NXT — Installation and Service Manual

107

Control Systems

Depending on the size of the Routing switcher, this bus may require inter-
mediate buffering through a CB-3000 Control Buffer. A CB 3000 is required
in the following cases:

TRX-NXT-128x128 - eight or more frames

TRX-NXT-256x256 - four or more frames

TRX-NXT-512x512 - two or more frames

TRX-NXT-128x256 - four or more frames

TRX-NXT-256x512 -two or more frames

TRX-NXT-256x512 -more than one frame

The CB-3000 is described in detail in the Jupiter Installation and Operating
manual.

In Trinix applications, the Crosspoint bus must be terminated at the point
farthest from the control processor using a Crosspoint Bus Terminator.

The CC-2010 is a 10-conductor (plus ground) cable. Ready-made cables,
with installed 15-pin D male connectors, are available from Grass Valley.

All rear-panel Crosspoint bus connectors are 15-pin D, female.

For those who wish to prepare their own cables, pin-outs are shown in

Figure 125 on page 216

. The cable itself should be Belden 9505 or equiva-

lent. User-supplied matrix cables for VDE installations require a ferrite core
over each end of the cable, adjacent to the connector. Details concerning
ferrite cores are given on

page 216

.

Jupiter Control System Installation

Refer to the Jupiter VM-3000 System Controller Installation and Operation
Manual or the Jupiter CM-4000 System Controller Installation and Opera-
tion Manual for the Installation instructions.

This manual is related to the following products: