beautypg.com

Ascii code details – Measurement Computing TempScan/1100 User Manual

Page 263

background image

TempScan/MultiScan, Appendix B

889597

IEEE488, Serial, & ASCII B-5

…… A-

ASCII Code Details

…… A-Decimal Values 00 to 31 – ACG & UCG Characteristics

ASCII Control Codes (Decimal 00 to 31)

Dec

Value

Hex

…… A-Value

($)

Character &

Abbreviation

…… A-Name

…… A-Bus Message

Addressed Command Group (

ACG

)

00

$00

…… A-

None

/ NUL

Null None

01

$01

^A / SOH

Start of Header

Go To Local (

GTL

)

02

$02

^B / STX

Start of Text

None

03

$03

^C / ETX

End of Text

None

04

$04

^D / EOT

End of Transmission

Selected Device Clear (

SDC

)

05

$05

^E / ENQ

Inquiry None

06

$06

^F / ACK

Acknowledgment None

07

$07

^G / BEL

Bell

Parallel Poll Disable (

PPD

)

08

$08

^H / BS

Backspace

Group Execute Trigger (

GET

)

09

$09

^I / HT

Horizontal Tab

Take Control (

TCT

)

10

$0A

^J / LF

Line Feed

None

11

$0B

^K / VT

Vertical Tab

None

12

$0C

^L / FF

Form Feed

None

13

$0D

^M / CR

Carriage Return

None

14

$0E

^N / SO

Shift Out

None

15

$0F

^O / SI

Shift In

None

Universal Command Group (

UCG

)

16

$10

^P / DLE

Data Link Escape

None

17

$11

^Q / DC1

Device Control 1

Local Lockout (

LLO

)

18

$12

^R / DC2

Device Control 2

None

19

$13

^S / DC3

Device Control 3

None

20

$14

^T / DC4

Device Control 4

Device Clear (

DCL

)

21

$15

^U / NAK

Negative Acknowledgment

Parallel Poll Unconfig (

PPU

)

22

$16

^V / SYN

Synchronous Idle

None

23

$17

^W / ETB

End of Transmission Block

None

24

$18

^X / CAN

Cancel

Serial Poll Enable (

SPE

)

25

$19

^Y / EM

End of Medium

Serial Poll Disable (

SPD

)

26

$1A

^Z / SUB

Substitute None

27

$1B

^[ / ESC

Escape None

28

$1C

^\ / FS

File Separator

None

29

$1D

^] / GS

Group Separator

None

30

$1E

^^ / RS

Record Separator

None

31

$1F

^_ / US

Unit Separator

None

Notes:

ASCII control codes are sometimes used to “formalize” a communications session between

communication devices.

DC1, DC2, DC3, DC4, FS, GS, RS,

and

US

all have user-defined meanings, and may vary

in use between sessions or devices.

DC4

is often used as a general “stop transmission character.”

Codes used to control cursor position may be used to control print devices, and move the print

head accordingly. However, not all devices support the full set of positioning codes.

This manual is related to the following products: