A-6 API Command Reference

889897

TempScan / MultiScan User’s Manual

Command Summary

Command

Syntax

Description

@

Trigger On Command

@

Trigger on receipt of an

@

.

*B

Flush Acquisition

Buffer

*B

Flush any data currently in the Acquisition Buffer.

*C

Clear Channel

Configuration

*C

Clear out the channel configuration so that no channels are

configured.

*F

Restore Factory

Settings

*F

Restore unit to factory configuration.

*Ggain

Set RTD Gain Calibration reference point to specified number

of ohms. gain is the reference point in the form of a real
number nnn.nn

*G

Set RTD Gain

Calibration
Reference

(TempScan/1100 only)

G?

Query the present reference point setting

*K

Change Calibration

Keyword

*Kkey

Change the calibration keyword where key is the keyword in

the form of a 5-digit number nnnnn. Therefore the
password can be no longer than 5 characters.

*P

Adjust Calibration Card

Pots

*Pchan

Select voltage level to be enabled for adjustment. Valid

options for chan are 01 – Enable –4.4 Volt Source on
calibration card. 02 – Enable +4.4 Volt Source on calibration
card. and 03 – Select 0 Volts Ground.

*R

Reset Power-On

*R

Power-on reset. Equivalent to a hardware reset.

*S

Set Power-Up

Configuration

*Smode

Specify power-up configuration mode. Valid options for mode

are 0 – Power-up under last known configuration (default)
and 1 – Power-up under factory default configuration.

*T

Set Scan Time

Stamping

*Tstate

Specify whether or not scan time stamping will be enabled.

Valid options for state are: 0 – Disable scan time stamping
(default), 1 – Enable absolute time stamping, and 2 – Enable
relative time stamping.

*W

Set Software Digital

Filtering
(TempScan/1100
only)

*Wmode

Specify whether or not software digital filtering for

thermocouple cards will be enabled. Valid options for mode
are: 0 – Disable digital filtering for thermocouple cards, and
1 – Enable digital filtering for thermocouple cards (default)

Achans,

output

Set alarm condition where chans is the channel(s) to assign to

the digital output.

chans may be in two forms: chan (for a single channel where

1

[[[[chan [[[[ max) or first – last (for a range of channels where

1

[[[[ first < last [[[[ max), where max = 992 for the

TempScan/1100 and max = 744 for the MultiScan/1200.

output is the digital output number to associate the channel(s)

with, where 1<=output<=32, and 0 is null.

A

Assign Alarm Output

A?

Query channels assigned to digital output.

A#

Set Scan Alarm
Stamping

A#state

Specify whether or not scan alarm stamping will be enabled.

Valid options for state are 0 – Disable scan alarm stamping
(default), and 1 – Enable scan alarm stamping.

Cchans,

type

[,

[lowsp],[
highsp],
[hyst] ]

Configure the channels for the master unit and its slave units.

chans and type are required arguments, while lowsp,
highsp and hyst are optional.

chans may be in two forms: chan (for a single channel where 1

[[[[ chan [[[[ max) or first – last (for a range of channels where

1

[[[[ first < last [[[[ max), where max = 992 for the

TempScan/1100 and max744 for the MultiScan/1200.
The chassis is chan = 0.

type is the type to assign to those channels. 0 is null.

C

Configure Channels

C?

Query current channel configuration