TempScan / MultiScan User’s Manual

889897

API

Command Reference A-7

Command

Syntax

Description

C#

Select Card

C#card

Select the card from which subsequent

QC?

and

U12

interrogation will retrieve information. Valid options for

card

are:

0

- Selects the chassis,

1

- Selects the card in

the master unit,

2

- Selects the 1st slave card,

3

- Selects

the 2nd slave card,

4

- Selects the 3rd slave card, etc,

30

-

Selects the 29th slave card, and

31

- Selects the 30th slave

card.

D#

Set Relay Make Time
(MultiScan/1200 only)

D#make

Specify how long to wait after closing a channel relay before

reading valid data, where

make

is the number of 520.833-

microsecond intervals.

E

End Calibration Mode

E

Terminate Calibration Mode

E?

Query Error Status

E?

Returns present error condition of the unit with one of the

following error codes:

E128

- Command Conflict Error.

E032

- Open Thermocouple or Range Error.

E016

- Trigger Overrun.

E008

- Calibration Error.

E004

- Channel Configuration Error.

E002

- Invalid Device Dependent Command Option (IDDCO).

E001

- Invalid Device Dependent Command (IDDC).

E000

- No error has occurred.

Fengr,

format

Configure the input and output formats.

engr

converts the raw data to the engineering units that you

prefer to work with. Valid options are:

0

- degrees Celsius

(default),

1

- degrees Fahrenheit,

2

- degrees Rankine,

3

-

degrees Kelvin, and

4

- Volts.

format

places the readings in a format that you prefer to

work with. Valid options are:

0

- Engineering Units (default),

1

- Binary (Low Byte/High Byte),

2

- Binary (High Byte/Low

Byte), and

3

- Counts (ASCII).

F

Set Data Format

F?

Query the data format.

F#

Set Burst Mode

Frequency

(MultiScan/1200 only)

F#freq

Select burst mode sampling frequency where

freq

is a real

number and where

38.5

<

freq

<

20000.0

Hertz

(default).

G

Calibrate Channel Gain

Gchan,

type

Calibrate the correction gain constants for given option card

where

chan

is the channel number such that

1

<

chan

<

max

, where

max

=

992

for the TempScan/1100 and

max

=

744

for the MultiScan/1200. The chassis is

chan = 0

.

type

is the channel type.

H

Calibrate Channel

Offset

Hchan

Calibrate the correction offset constants for given option card

where

chan

is the channel number such that

1

<

chan

<

max

, where

max

=

992

for the TempScan/1100 and

max

=

744

for the MultiScan/1200. The chassis is

chan = 0

.

Inorm,

acq

Set the two configurable scan intervals of the unit where

norm

and

acq

are the normal and acquisition scan intervals which

have the form:

hh:mm:ss.t

where

hh

is hours,

mm

is

minutes,

ss

is seconds, and t is tenths of a second.

I

Set Scan Interval

I?

Query scan interval selection.

I#

Set Digital Input

Stamping

I#state

Specify whether or not digital input stamping will be enabled.

Valid options for

state

are:

0

- Disable digital input

stamping (default), and

1

- Enable digital input stamping.