Calibration

Calibration of cold junction sensor: Software control of calibrated thermocouple using ChartView’s

built-in calibration feature. The automated calibration function is accessed from ChartView’ Device
pull-down menu using “Select Status” and then selecting “Calibration.” Note that calibration is
performed for each card and chassis in the system.

Voltage Calibration: Software control of gain and offset.
Calibration Constants: Chassis constants stored in NV-RAM. Card constants stored in card’s on-board

EEPROM.

Hardware Configuration

The TempScan/1100 or MultiScan/1200 unit is equipped with a high-speed IEEE 488 interface and an
RS-232 interface. Its IEEE 488 interface is useful in laboratory applications and enables real-time transfers
of acquired data to the host computer’s hard drive for inexpensive mass storage.
Its RS-232 interface is ideal in applications that require the placement of instrumentation at remote
distances from the controlling computer, such as process and environmental control.

This unit can be set up with an IEEE 488 or a RS-232 interface configuration, as determined by the DIP
switch accessible from the rear panel. This DIP switch via its nine microswitches select which command
set is to be used – IEEE 488 or RS-232 – and the operating parameters for each.
The table shows the options for its nine microswitches. Additional DIP switch settings are shown in the
following sections.

Rear Panel DIP Switch

Micro-

Label

Setting

Description

switch #

IEEE 488

RS-232

1

COMM SELECT

0

IEEE 488

(N/A)

1

(N/A) RS-232

2,3

HANDSHAKE (H/S)

00

No Handshake

No Handshake

01

Software Handshake only

(XON/XOFF) (See Note)

Software Handshake only

(XON/XOFF) (See Note)

10

Hardware Handshake only

(RTS/CTS)

Hardware Handshake only

(RTS/CTS)

11

Both Hardware and Software

Handshake

Both Hardware and Software

Handshake

4,5

IEEE ADDRESS or

00

Decimal value 0

No Parity

PARITY

01

Decimal value 8

Odd Parity

10

Decimal value 16

Even Parity

11

Decimal value 24

(N/A)

6,7,8

IEEE ADDRESS or

000

Decimal value 0

300 baud

BAUD RATE

001

Decimal value 1

600 baud

010

Decimal value 2

1200 baud

011

Decimal value 3

2400 baud

100

Decimal value 4

4800 baud

101

Decimal value 5

9600 baud (See Note)

110

Decimal value 6

(N/A)

111

Decimal value 7

(N/A)

9

CHASSIS 0

Disabled

Disabled

CALIBRATION

ENABLE

1 Enabled

Enabled

Note: (1) XON/XOFF handshaking is valid for ASCII transmissions only. (2) At 9600 baud,

hardware (RTS/CTS) handshaking and possibly software (XON/XOFF) handshaking may be
required to maintain serial performance.