Basler Electric DGC-2020HD User Manual

Page 51

background image

9469300990 Rev B

41

VOLT

AMP

PH

Hz

OIL

FUEL/DEF†

TEMP

BATT

∗ When set to standard, individual phase information can be automatically toggled at a rate set by the
Phase Toggle Delay setting. Navigate to the Settings, General Settings, Front Panel HMI screen and edit
Phase Toggle Delay. When the Phase Toggle Delay is set to zero, information for each phase is obtained
by pressing the Up or Down arrow keys on the front panel. When it is set to a number other than zero, the
display will toggle through the phases automatically at the rate specified by the Phase Toggle Delay
Setting.

† When a Selective Catalytic Reduction (SCR) with Diesel Exhaust Fluid (DEF) exhaust after-treatment
system is implemented, the overview screen automatically alternates the display of FUEL level and DEF
level.

When the overview screen is set to scrolling, you can select/configure the metering values that are
displayed. Up to 20 values can be displayed and these values will scroll at a delay time specified by the
user. To select a scrolling overview, navigate to the Settings, General Settings, Front Panel HMI, Scrolled
Metering screen and set the Scroll Enable setting to Enabled. The Scroll Delay setting is also found on
this screen.

To select the scrolling values, navigate to the Settings, General Settings, Front Panel HMI screen and edit
the Configurable Metering. The following parameters may be placed in the scrolling overview:

Alarm Silence

Alternate Frequency Override

Analog Expansion Module 1 Inputs 1 to 8

Analog Expansion Module 1 RTDs 1 to 8

Analog Expansion Module 1 Thermos 1 and 2

Analog Expansion Module 2 Inputs 1 to 8

Analog Expansion Module 2 RTDs 1 to 8

Analog Expansion Module 2 Thermos 1 and 2

Analog Expansion Module 3 Inputs 1 to 8

Analog Expansion Module 3 RTDs 1 to 8

Analog Expansion Module 3 Thermos 1 and 2

Analog Expansion Module 4 Inputs 1 to 8

Analog Expansion Module 4 RTDs 1 to 8

Analog Expansion Module 4 Thermos 1 and 2

Analog Inputs 1 to 4

Analog Output AVR

Analog Output GOV

Analog Output LS

Battery Voltage

Boost Pressure

Bus1 average voltage

Bus1 complex power Phase A

Bus1 complex power Phase B

Bus1 complex power Phase C

Bus1 Current Phase A

Bus1 Current Phase B

Bus1 Current Phase C

Bus1 Dead

Bus1 Failed

Contact Expansion Module 2 Inputs 1 to 10

Contact Expansion Module 3 Inputs 1 to 10

Contact Expansion Module 4 Inputs 1 to 10

Contact Inputs 1 to 16

Contact Output Prestart

Contact Output Run

Contact Output Start

Contact Outputs 1 to 12

Coolant Level Settings

Coolant Pressure

Coolant Temperature

Cooldown and Stop Request

Cooldown Request

Cooldown Timer Active

Date

Device ID

Engine Load

Engine Running

Engine Speed (RPM)

EPS Supplying Load

External Start Delay

Fuel Level / Diesel Exhaust Fluid Level

Fuel Pressure

Fuel Rate

Fuel Temperature

Generator average voltage

Generator complex power Phase A

Generator complex power Phase B

Generator complex power Phase C

DGC-2020HD

Controls and Indicators