Up to three LED indicators may be programmed to suit the needs of a particular application. A
replaceable card (Figure 15) is provided that can be labeled to match the function of each programmable
indicator.

Figure 15. Programmable Indicator Label Card

Information about configuring DGC-2020HD logic to control the programmable indicators can be found in
the BESTlogic™Plus chapter.

To label the programmable indicators, perform the following steps.

1.

Print the label text on readily-available address label sheets. The label card accommodates
adhesive-backed labels measuring 0.5 by 1.75 inches. Avery part number 18167 is suitable for
this purpose.

2.

Remove all control power from the DGC-2020HD.

3.

Remove the fasteners from the four mounting studs on the DGC-2020HD and separate it from the
mounting panel or optional escutcheon plate. Disconnect the nine terminal block connectors; the
Start, Run, and Pre relays; and the Ethernet (copper or fiber), USB, and DB-9 connectors.

4.

Lay the front panel face-down on a suitable work surface.

5.

Grasp the tab of the label card and pull free. The label card tab is located on the rear of the DGC-
2020HD, see Figure 16. When facing the back of the panel, the label card tab is on the left.

6.

Apply the labels created in step 1 to the label cards. The rectangle outlines on the label card
serve as guides for attaching the labels.

7.

After applying the new labels, insert the label card into the slot. Ensure that the label card is
oriented properly by viewing the custom labels through the label windows of the front panel.

8.

Move the DGC-2020HD adjacent to the mounting panel or optional escutcheon plate and
reconnect the cables removed in step 3.

9.

Secure the DGC-2020HD to the mounting panel or optional escutcheon plate with the fasteners
removed in step 3. The torque applied to the mounting hardware should not exceed 20 inch-
pounds or 2.2 newton meters.

10.

If desired, verify the function of the programmed indicators before returning the DGC-2020HD to
service.