Rockwell Automation 284 ArmorStart User Manual User Manual
Page 85

Bulletin 280/281 Programmable Parameters
3-23
Zone #3 EPR
The Expected Packet Rate in
msec. for the zone 1 consuming
connection. If consumed data is
not received in 4 times this
value, the zone connection will
time out and “Zone #3 Health”
will report 1 = Not Healthy.
Parameter Number
88
Access Rule
GET/SET
Data Type
UNIT
Group
ZIP Parameters
Units
msec
MinimumValue
0
Maximum Value
65535
Default Value
75
Zone #4 EPR
The Expected Packet Rate in
msec. for the zone 1 consuming
connection. If consumed data is
not received in 4 times this
value, the zone connection will
time out and “Zone #4 Health”
will report 1 = Not Healthy.
Parameter Number
89
Access Rule
GET/SET
Data Type
UNIT
Group
ZIP Parameters
Units
msec
MinimumValue
0
Maximum Value
65535
Default Value
75
Zone #1 Control
Zone 1 Control Word. Default
Bit 0 and Bit 1 set, all other bits
clear.
Bit0=Security Enable 1=Enable
data security
Bit1=COS Cnxn 1=Consume
DNet Group 2 COS messages
Bit2=Poll Cnxn
1=Consume DNet Group 2 Poll
Response msgs.
Bit3=Strobe Cnxn
1=Consume DNet Group 2
Strobe Response msgs.
Bit4=Multicast Poll
1=Consume Multicast Poll
Response messages.
Parameter Number
90
Access Rule
GET/SET
Data Type
BYTE
Group
ZIP Parameters
Units
—
MinimumValue
0
Maximum Value
255
Default Value
3