Bulletin 284 Programmable Parameters for Volts per Hertz Controllers
5-21
Wiring Options
Bit 0 = Conduit
Bit 1 = Round Media
Bits 2-15 = Reserved
Parameter Number
58
Access Rule
GET
Data Type
WORD
Group
Misc.
Units
—
Minimum Value
0
Maximum Value
Default Value
0
Starter Enclosure
Bit 0 = IP67
Bit 1 = NEMA 4x
Bits 2-15 reserved
Parameter Number
59
Access Rule
GET
Data Type
WORD
Group
Misc.
Units
—
Minimum Value
0
Maximum Value
65535
Default Value
0
Starter Option
Bit 0 = HOA Keypad
Bit 1 = Safety Monitor
Bit 2 = Source Brake
Bit 3 = Control Brake
Bit 4 = Dynamic Brake
Bit 5 = Output Contactor
Bit 6 = EMI Filter
Bit 7 = 0-10V Analog In
Bits 8-15 = Reserved
Parameter Number
60
Access Rule
GET
Data Type
WORD
Group
Misc.
Units
—
Minimum Value
0
Maximum Value
66535
Default Value
0