5-32
Bulletin 284 Programmable Parameters for Volts per Hertz Controllers
Drive Status
Present operating condition of the drive.
Bit 0 = running
Bit 1 = Forward
Bit 2 = Accelerating
Bit 3 = Decelerating
Parameter Number
106
Related Parameter
195
Access Rule
GET
Data Type
WORD
Group
Display Group
Units
—
Minimum Value
0
Maximum Value
1
Default Value
Read Only
Fault 1 Code
A code that represents drive fault. The code will appear in this parameter as the
most recent fault that has occurred.
Parameter Number
107
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
—
Minimum Value
F122
Maximum Value
F2
Default Value
Read Only
Fault 2 Code
A code that represents a drive fault. The code will appear in this parameter as the
second most recent fault that has occurred.
Parameter Number
108
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
—
Minimum Value
F122
Maximum Value
F2
Default Value
Read Only
Fault 3 Code
A code that represents a drive fault. The code will appear in this parameter as the
third most recent fault that has occurred.
Parameter Number
109
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
—
Minimum Value
F122
Maximum Value
F2
Default Value
Read Only
Process Display
The output frequency scaled by the process factor (Parameter 199).
Parameter Number
110
Related Parameter
101, 199, 215, 216
Access Rule
GET
Data Type
LINT
Group
Display Group
Units
0.01…1
Minimum Value
0.00
Maximum Value
9999
Default Value
Read Only