Zip parameters – Rockwell Automation 284 ArmorStart User Manual User Manual
Page 80

3-18
Bulletin 280/281 Programmable Parameters
ZIP Parameters
Base Options
Indicates the options for the
ArmorStart Base unit
Bit 0 = Output Fuse
Bit 1 = Safety Monitor
Bit 2 = CP Fuse Detect
Bits 3-7 = Reserved
Bit 8 = 10A Base
Bit 9 = 25A Base
Bit 10-15 = Reserved
Parameter Number
57
Access Rule
GET
Data Type
WORD
Group
Misc.
Units
—
MinimumValue
0
Maximum Value
65535
Default Value
0
Wiring Options
Bit 0 = Conduit
Bit 1 = Round Media
Bits 2-15 = Reserved
Parameter Number
58
Access Rule
GET
Data Type
WORD
Group
Misc.
Units
—
MinimumValue
0
Maximum Value
65535
Default Value
0
Starter Enclosure
Bit 0 = IP67
Bit 1 = NEMA 4x
Bits 2-15 reserved
Parameter Number
59
Access Rule
GET
Data Type
WORD
Group
Misc.
Units
—
MinimumValue
0
Maximum Value
65535
Default Value
—
Starter Option
Bit 0 = HOA Keypad
Bit 1 = Safety Monitor
Bit 2 = Source Brake
Bits 4-15 = Reserved
Parameter Number
60
Access Rule
GET
Data Type
WORD
Group
Misc.
Units
—
MinimumValue
0
Maximum Value
66535
Default Value
—
AutoRun Zip
Enables ZIP data production on
power up
0=Disable
1=Enable
Parameter Number
67
Access Rule
Get/Set
Data Type
BOOL
Group
ZIP Parameters
Units
MinimumValue
0
Maximum Value
1
Default Value
0