Rockwell Automation 284 ArmorStart User Manual User Manual
Page 147

Bulletin 284 Programmable Parameters for Volts per Hertz Controllers
5-25
Zone #3 MAC ID
The node address of the device whose data is to be consumed for zone 3. When set
to the value 64, data consumption is disabled.
Parameter Number
72
Access Rule
GET/SET
Data Type
USINT
Group
ZIP Parameters
Units
—
Minimum Value
0
Maximum Value
64
Default Value
64
Zone #4 MAC ID
The node address of the device whose data is to be consumed for zone 4. When set
to the value 64, data consumption is disabled.
Parameter Number
73
Access Rule
GET/SET
Data Type
USINT
Group
ZIP Parameters
Units
—
Minimum Value
0
Maximum Value
64
Default Value
64
Zone #1 Health
Read Only consumed connection status for zone 1
0 = Healthy
1 = Unhealthy
Parameter Number
74
Access Rule
GET
Data Type
BOOL
Group
ZIP Parameters
Units
—
Minimum Value
0
Maximum Value
1
Default Value
0
Zone #2 Health
Read Only consumed connection status for zone 2
0 = Healthy
1 = Unhealthy
Parameter Number
75
Access Rule
GET
Data Type
BOOL
Group
ZIP Parameters
Units
—
Minimum Value
0
Maximum Value
1
Default Value
0
Zone #3 Health
Read Only consumed connection status for zone 3
0 = Healthy
1 = Unhealthy
Parameter Number
76
Access Rule
GET
Data Type
BOOL
Group
ZIP Parameters
Units
—
Minimum Value
0
Maximum Value
1
Default Value
0