Display group – Rockwell Automation 284 ArmorStart User Manual User Manual
Page 196
![background image](/manuals/577766/196/background.png)
6-22
Bulletin 284 Programmable Parameters for Sensorless Vector Controllers
Display Group
Output Freq
Output frequency present at T1, T2, T3.
Parameter Number
101
Related Parameters
102, 110, 134, 135, 138
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
0.1 Hz
Minimum Value
0.0
Maximum Value
400.0 Hz
Default Value
Read Only
Commanded Freq
Value of the active frequency command. Displays the commanded frequency even if
the drive is not running.
Parameter Number
102
Related Parameters
101, 113, 134, 135, 138
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
0.1 Hz
Minimum Value
0.0
Maximum Value
400.0 Hz
Default Value
Read Only
Output Current
Output Current present at T1, T2, T3.
Parameter Number
103
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
0.01
Minimum Value
0.00
Maximum Value
Drive rated amps x 2
Default Value
Read Only
Output Voltage
Output Current present at T1, T2, T3.
Parameter Number
104
Related Parameters
131, 184, 188
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
1V AC
Minimum Value
0
Maximum Value
230V, 460V, or 600V AC
Default Value
Read Only
DC Bus Voltage
Present DC Bus voltage level.
Parameter Number
105
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
1V DC
Minimum Value
Based on Drive Rating
Maximum Value
Default Value
Read Only