Bulletin 283 CIP Information
C-15
Table C.33 Connection Object Instance 8-11 Attributes
The following services are implemented for the Connection Object:
Table C.34 Connection Objects Common Services
Attribute
ID
Access
Rule
Name
Data Type
Value
1
Get
State
USINT
0=nonexistant
1=configuring
3=established
2
Get
Instance Type
USINT
1=I/O Connection
3
Get
Transport Class Trigger
USINT
0x20 (COS,
unacknowledged)
4
Get
Produced Connection ID
UINT
FFFF (not producing data)
5
Get
Consumed Connection ID
UINT
01101xxxxxx
xxxxxx=node address
6
Get
Initial Comm Characteristics
USINT
0xF0 (unacknowledged)
7
Get
Produced Connection Size
UINT
0
8
Get
Consumed Connection Size
UINT
8
9
Get/Set
Expected Packet Rate
UINT
in milliseconds
12
Get
Watchdog Action
USINT
2=auto reset
13
Get
Produced Connection Path Length
UINT
0
14
Get
Produced Connection Path
0
15
Get
Consumed Connection Path Length
UINT
8
16
Get
Consumed Connection Path
21 0E 03 25 01 00 30 02
Service
Code
Implemented for:
Service
Name
Class
Instance
0x05
No
Yes
Reset
0x0E
No
Yes
Get_Attribute_Single
0x10
No
Yes
Set_Attribute_Single