Bulletin 284 Programmable Parameters for Volts per Hertz Controllers
5-33
Control Source
Displays the source of the Start Command and Speed Reference.
Valid Start Commands for the Bulletin 284 ArmorStart are the following:
2 = 2-wire
3 = 2-wire Level Sensitive
4 = 2-wire High Speed
5 = RS485 (DSI) Port
9 = Jog
Valid Speed Commands for the Bulletin 284 ArmorStart are the following:
1 = Internal Frequency
4 = Preset Freq X
5 = RS485 (DSI) port
9 = Jog Freq
Parameter Number
112
Related Parameters
136, 138, 151, 152
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
1
Minimum Value
0
Maximum Value
9
Default Value
5
Contrl In Status
Status of the control terminal block control inputs:
Bit 0 = Start/Run FWD input
Bit 1 = Direction/Run REV Input
Bit 2 = Stop Input
Bit 3 = Reserved
Parameter Number
113
Related Parameters
102, 134, 135
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
1
Minimum Value
0
Maximum Value
15
Default Value
0
Dig In Status
Status of the control terminal block digital inputs:
Bit 0 = Digital IN 1 Sel
Bit 1 = Digital IN 2 Sel
Bit 2 = Reserved
Bit 3 = Reserved
Parameter Number
114
Related Parameters
151, 152
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
1
Minimum Value
0
Maximum Value
15
Default Value
0
Comm Status
Status of communications ports:
Bit 0 = Receiving Data
Bit 1 = Transmitting Data
Bit 2 = RS485
Bit 3 = Communication Error
Parameter Number
115
Related Parameters
203…207
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
1
Minimum Value
0
Maximum Value
15
Default Value
0
Control SW Ver
Main Control Board software version for AC Drive.
Parameter Number
116
Access Rule
GET
Data Type
UINT
Group
Display Group
Units
0.01
Minimum Value
1.00
Maximum Value
99.99
Default Value
Read Only