Zip parameters – Rockwell Automation 284 ArmorStart User Manual User Manual
Page 146

5-24
Bulletin 284 Programmable Parameters for Volts per Hertz Controllers
ZIP Parameters
AutoRun Zip
Enables ZIP data production on power up
0=Disable
1=Enable
Parameter Number
67
Access Rule
GET/SET
Data Type
BOOL
Group
ZIP Parameters
Units
—
Minimum Value
0
Maximum Value
1
Default Value
0
Zone Produced EPR
The Expected Packet Rate in msec. Defines the rate of at which ZIP data is
produced. Defaults to 75 msec.
Parameter Number
68
Access Rule
GET/SET
Data Type
UINT
Group
ZIP Parameters
Units
msec
Minimum Value
0
Maximum Value
65535
Default Value
75
Zone Produced PIT
The Production Inhibit Time in msec. Defines the minimum time between Change of
State data production
Parameter Number
69
Access Rule
GET/SET
Data Type
UINT
Group
ZIP Parameters
Units
msec
Minimum Value
0
Maximum Value
65535
Default Value
75
Zone #1 MAC ID
The node address of the device whose data is to be consumed for zone 1. When set
to the value 64, data consumption is disabled. .
Parameter Number
70
Access Rule
GET/SET
Data Type
USINT
Group
ZIP Parameters
Units
—
Minimum Value
0
Maximum Value
64
Default Value
64
Zone #2 MAC ID
The node address of the device whose data is to be consumed for zone 2. When set
to the value 64, data consumption is disabled.
Parameter Number
71
Access Rule
GET/SET
Data Type
USINT
Group
ZIP Parameters
Units
—
Minimum Value
0
Maximum Value
64
Default Value
64