Zip parameters – Rockwell Automation 284 ArmorStart User Manual User Manual
Page 112
4-22
Bulletin 283 Programmable Parameters
ZIP Parameters
AutoRun Zip
Enables ZIP data production on
power up
0=Disable
1=Enable
Parameter Number
67
Access Rule
GET/SET
Data Type
BOOL
Group
ZIP Parameters
Units
MinimumValue
0
Maximum Value
1
Default Value
0
Zone Produced EPR
The Expected Packet Rate in
msec. Defines the rate at which
ZIP data is produced. Defaults to
75 msec.
Parameter Number
68
Access Rule
GET/SET
Data Type
UINT
Group
ZIP Parameters
Units
msec
MinimumValue
0
Maximum Value
65535
Default Value
75
Zone Produced PIT
The Production Inhibit Time in
msec. Defines the minimum
time between Change of State
data production
Parameter Number
69
Access Rule
GET/SET
Data Type
UINT
Group
ZIP Parameters
Units
msec
MinimumValue
0
Maximum Value
65535
Default Value
75
Zone #1 MAC ID
The node address of the device
whose data is to be consumed
for zone 1
Parameter Number
70
Access Rule
GET/SET
Data Type
USINT
Group
ZIP Parameters
Units
—
MinimumValue
0
Maximum Value
64
Default Value
64
Zone #2 MAC ID
The node address of the device
whose data is to be consumed
for zone 2
Parameter Number
71
Access Rule
GET/SET
Data Type
USINT
Group
ZIP Parameters
Units
—
MinimumValue
0
Maximum Value
64
Default Value
64