Bulletin 283 Programmable Parameters

Misc. Group

Keypad Mode

This parameter selects if the
keypad operation is maintained
or momentary

0= Maintained
1= Momentary

Parameter Number

45

Access Rule

GET/SET

Data Type

BOOL

Group

Misc.

Units

Minimum Value

0

Maximum Value

1

Default Value

0

Keypad Disable

This parameter disables all
keypad function except for the
“OFF” and “RESET” buttons

0=Not Disabled
1=Disabled

Parameter Number

46

Access Rule

GET/SET

Data Type

BOOL

Group

Misc.

Units

Minimum Value

0

Maximum Value

1

Default Value

0

Set to Defaults

This parameter if set to 1 will set
the device to the factory defaults

0=No Operation
1=Set to Defaults

Parameter Number

47

Access Rule

GET/SET

Data Type

BOOL

Group

Misc.

Units

Minimum Value

0

Maximum Value

1

Default Value

0

Base Enclosure

Indicates the ArmorStart Base
unit enclosure rating

Bit 0 = IP67
Bit 1 = NEMA 4X
Bit 2-15 = Reserved

Parameter Number

56

Access Rule

GET

Data Type

WORD

Group

Misc.

Units

MinimumValue

0

Maximum Value

65535

Default Value

0