Bulletin 284 Programmable Parameters for Volts per Hertz Controllers
Zone #4 KEY
When the “Security Enable” bit for zone 1 is enabled, this value must match the
value of the Device Value Key parameter in the device whose data is being
consumed for zone 4
Parameter Number
97
Access Rule
GET/SET
Data Type
UINT
Group
ZIP Parameters
Units
—
Minimum Value
0
Maximum Value
65535
Default Value
0
Device Value Key
This value is produced in the last 2 bytes of data when one of the ZIP assemblies is
chosen for data production.
Parameter Number
98
Access Rule
GET/SET
Data Type
UINT
Group
ZIP Parameters
Units
—
Minimum Value
0
Maximum Value
65535
Default Value
0
Zone Ctrl Enable
Global enable for ZIP peer-to-peer messaging. This parameter must be disabled
before any changes to the ZIP configuration for the device can be made.
0=Disable
1=Enable
Parameter Number
99
Access Rule
GET/SET
Data Type
BOOL
Group
ZIP Parameters
Units
—
Minimum Value
0
Maximum Value
1
Default Value
0