Setting the motor parameters for the servo control, Setting, 0x2c08 – Lenze i700 User Manual
Page 75: 0x3408, 5motor control & motor settings

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
75
5
Motor control & motor settings
5.8
Setting the motor parameters for the servo control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.8
Setting the motor parameters for the servo control
If the servo control (SM, ASM) is applied, it is required to parameterise the so-called motor model
first. These are electrical variables which are provided in the i700 servo inverter as parameters.
5.8.1
Lenze motor: Easy loading of motor data from the catalogue via the »PLC-Designer«
For Lenze motors with a standard feedback system installed by Lenze, the required motor
parameters are provided by the »PLC Designer« during the motor selection by means of catalogues
and automatically copied to the i700 servo inverter in the default setting.
In this case, you can directly go to the next commissioning step:
Setting the feedback system for the servo control
5.8.2
Motors of other manufacturers or no catalogue data available: Three possibilities to create
the setting
For motors of other manufacturers or if there are no catalogue data available for the motor, three
alternative possibilities for setting the motor parameters are provided:
A.
(and have motor model parameters determined automatically)
Determine motor parameters automatically via "motor parameter identification"
The following subchapters provide detailed information on the three alternative methods. The
Engineering tool saves the used method to the following object so that the suitable
parameterisation dialogs are available the next time an online connection is present.
0x2C08 | 0x3408 - motor: Setting method - motor parameters
Selection list
(Lenze setting printed in bold)
Info
1 Select from catalogue (Lenze motor)
For Lenze motors with a standard feedback system
installed by Lenze, the required motor parameters are
provided by the »PLC Designer« during the motor
selection by means of catalogues and automatically
copied to the i700 servo inverter in the default setting.
2 Enter motor nameplate data (other motors)
(and have motor model parameters determined
automatically)
3 Manually (other motors)
4 Identification in progress (all motors)
Determine motor parameters automatically via
"motor parameter identification"
Write access CINH OSC P RX TX
UNSIGNED_8