189
7
CiA402 device profile
7.4
Device control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.4.3
Selection of the operating mode
The drive behaviour depends on the selected operating mode. The operating mode is selected by the
object (or
for axis B) in the communication statuses "Pre-
Operational" or "Operational". Access can be effected via SDO or PDO.
• Only one operating mode at a time can be active.
• The operating modes differ by the type of setpoint selection.
• The following table shows the permissible operating modes with the corresponding object
value:
Tip!
The operating mode currently set can be read via the
object (or
For this object, too, access is possible via SDO or PDO.
Modes of operation
Object value
Setpoint selection
2
Velocity
Cyclic sync position mode (csp)
8
Position
Cyclic sync velocity mode (csv)
9
Velocity
10
Torque
-
All other values
- (Standstill)