0x2b06 | 0x3306 - vfc: voltage boost, 4 setting the load adjustment, 0x2b07 | 0x3307 - vfc: load adjustment parameter – Lenze i700 User Manual
Page 142: Setting the load adjustment, 0x2b06, 0x3306, 0x2b07, 0x3307, 5motor control & motor settings, Stop

5
Motor control & motor settings
5.14
Parameterising the V/f characteristic control
142
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
[5-11] Voltage boost for a linear V/f characteristic (left) and square-law V/f characteristic (right)
Tip!
For magnetising the motor, consider a sufficient time from the controller enable to the
start of the speed ramp function generator.
• The bigger the motor the longer the time required for magnetisation. A motor with a
power of 90 kW requires up to 2 seconds.
0x2B06 | 0x3306 - VFC: Voltage boost
5.14.4
Setting the load adjustment
0x2B07 | 0x3307 - VFC: Load adjustment parameter
0
0
U
Boost
0
0
U
Boost
f
set
V
V
f
set
Frequency at ref. point
Voltage at ref. point
Voltage at ref. point
Frequency at ref. point
Voltage boost
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
V
100.0 0.0 V
Write access CINH OSC P RX TX
Scaling: 1/10
UNSIGNED_16
Stop!
If the load adjustment is too high, the motor current may increase in idle state and the
motor may overheat!
Sub.
Name
Lenze setting
Data type
VFC: Load adjustment - direction of rotation
0: Passive load (e.g. friction)
UNSIGNED_8
VFC: Load adjustment - value
20.00 %
UNSIGNED_32
Subindex 1:
VFC: Load adjustment - direction of rotation
Adaptation of the characteristic depending on the load in the case of CW and CCW rotation
Selection list
(Lenze setting printed in bold)
Info
0 Passive load (e.g. friction)
The motor operates in motor mode in both directions.
1 Active load, CCW (e.g. hoist)
Application example: Hoist without counterweight
2 Active load, CW (e.g. hoist)
Application example: Dancer-controlled unwinder
Write access CINH OSC P RX TX
UNSIGNED_8