_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2C04 | 0x3404 - Motor: Lss saturation characteristic - inductance grid points (y)
0x2C05 | 0x3405 - Motor: Lss saturation charcteristic - reference for current grid points (x)
From version 01.05
, the correction by means of saturation characteristic via the subindex 18 can also be switched
off.
Sub.
Name
Lenze setting
Data type
1 Lss: y1 = L01 (x = 0.00 %)
165 %
UNSIGNED_16
2 Lss: y2 = L02 (x = 6.25 %)
200 %
UNSIGNED_16
3 Lss: y3 = L03 (x = 12.50 %)
146 %
UNSIGNED_16
4 Lss: y4 = L04 (x = 18.75 %)
117 %
UNSIGNED_16
5 Lss: y5 = L05 (x = 25.00 %)
97 %
UNSIGNED_16
6 Lss: y6 = L06 (x = 31.25 %)
82 %
UNSIGNED_16
7 Lss: y7 = L07 (x = 37.50 %)
71 %
UNSIGNED_16
8 Lss: y8 = L08 (x = 42.75 %)
62 %
UNSIGNED_16
9 Lss: y9 = L09 (x = 50.00 %)
55 %
UNSIGNED_16
10 Lss: y10 = L10 (x = 56.25 %)
50 %
UNSIGNED_16
11 Lss: y11 = L11 (x = 62.50 %)
46 %
UNSIGNED_16
12 Lss: y12 = L12 (x = 68.75 %)
43 %
UNSIGNED_16
13 Lss: y13 = L13 (x = 75.00 %)
42 %
UNSIGNED_16
14 Lss: y14 = L14 (x = 81.25 %)
41 %
UNSIGNED_16
15 Lss: y15 = L15 (x = 87.50 %)
41 %
UNSIGNED_16
16 Lss: y16 = L16 (x = 93.25 %)
41 %
UNSIGNED_16
17 Lss: y17 = L17 (x = 100.00 %)
41 %
UNSIGNED_16
18 Motor: Lss saturation characteristic -
Activation
1: Active
UNSIGNED_16
Write access CINH OSC P RX TX
Maximum motor current
• Serves as a reference value for the scaled current values of the X axis of the saturation characteristic.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
A
500.0 5.4 A
Write access CINH OSC P RX TX
Scaling: 1/10
UNSIGNED_16